HEC-RAS Version 4.1.0 Jan 2010

U.S. Army Corps of Engineers

Hydrologic Engineering Center

609 Second Street

Davis, California

 

 

X X XXXXXX XXXX XXXX XX XXXX

X X X X X X X X X X

X X X X X X X X X

XXXXXXX XXXX X XXX XXXX XXXXXX XXXX

X X X X X X X X X

X X X X X X X X X X

X X XXXXXX XXXX X X X X XXXXX

 

 

 

PROJECT DATA

Project Title: FlamWashEX

Project File : FlamWashEX.prj

Run Date and Time: 8/9/2013 3:26:16 AM

 

Project in English units

 

Project Description:

FLAMINGO WASH

PRE-PROJECT CONDITIONS MODEL

DATUM - NAVD88

FILE;

FlamWashPre.prj

STARTING WSE = NORMAL DEPTH

SUBCRITICAL RUN

FLAMINGO

WASH FIS RESTUDY

PHASE 1,2,3 OF FLAMINGO WASH INCLUDED

 

 

 

 

 

PLAN DATA

 

Plan Title: EX

Plan File : P:\ClarkCountyPubWorks\462579LVW\6_Permits\6_CLOMR-LOMR\4_CD\Hydraulic Models\Flamingo Wash\Corrected Effective\FlamWashEX.p03

 

Geometry Title: FlamWashEX

Geometry File : P:\ClarkCountyPubWorks\462579LVW\6_Permits\6_CLOMR-LOMR\4_CD\Hydraulic Models\Flamingo Wash\Corrected Effective\FlamWashEX.g01

 

Flow Title : FlamWashEX

Flow File : P:\ClarkCountyPubWorks\462579LVW\6_Permits\6_CLOMR-LOMR\4_CD\Hydraulic Models\Flamingo Wash\Corrected Effective\FlamWashEX.f01

 

Plan Summary Information:

Number of: Cross Sections = 43 Multiple Openings = 0

Culverts = 0 Inline Structures = 0

Bridges = 2 Lateral Structures = 0

 

Computational Information

Water surface calculation tolerance = 0.01

Critical depth calculation tolerance = 0.01

Maximum number of iterations = 20

Maximum difference tolerance = 0.3

Flow tolerance factor = 0.001

 

Computation Options

Critical depth computed only where necessary

Conveyance Calculation Method: At breaks in n values only

Friction Slope Method: Average Conveyance

Computational Flow Regime: Subcritical Flow

 

 

 

FLOW DATA

 

Flow Title: FlamWashEX

Flow File : P:\ClarkCountyPubWorks\462579LVW\6_Permits\6_CLOMR-LOMR\4_CD\Hydraulic Models\Flamingo Wash\Corrected Effective\FlamWashEX.f01

 

Flow Data (cfs)

River Reach RS PF 1

RIVER-1 Reach-1 390 6300

RIVER-1 Reach-1 140 6400

 

Boundary Conditions

River Reach Profile Upstream Downstream

RIVER-1 Reach-1 PF 1 Normal S = 0.004 Normal S = 0.004

 

 

GEOMETRY DATA

 

Geometry Title: FlamWashEX

Geometry File : P:\ClarkCountyPubWorks\462579LVW\6_Permits\6_CLOMR-LOMR\4_CD\Hydraulic Models\Flamingo Wash\Corrected Effective\FlamWashEX.g01

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 390

 

INPUT

Description:

Station Elevation Data num= 10

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1001796.847 1001786.847 116.751786.512 133.51786.847 133.51796.847

136.51796.847 136.51786.847 153.251786.512 1701786.847 1701796.847

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

100 .025 100 .015 170 .025

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

100 170 420.9 420.9 420.21 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1796.43 Element Left OB Channel Right OB

Vel Head (ft) 3.25 Wt. n-Val. 0.015

W.S. Elev (ft) 1793.18 Reach Len. (ft) 420.90 420.90 420.21

Crit W.S. (ft) 1793.18 Flow Area (sq ft) 435.43

E.G. Slope (ft/ft) 0.002698 Area (sq ft) 435.43

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 67.00 Top Width (ft) 67.00

Vel Total (ft/s) 14.47 Avg. Vel. (ft/s) 14.47

Max Chl Dpth (ft) 6.67 Hydr. Depth (ft) 6.50

Conv. Total (cfs) 121295.6 Conv. (cfs) 121295.6

Length Wtd. (ft) 420.90 Wetted Per. (ft) 92.34

Min Ch El (ft) 1786.51 Shear (lb/sq ft) 0.79

Alpha 1.00 Stream Power (lb/ft s) 170.00 0.00 0.00

Frctn Loss (ft) 1.14 Cum Volume (acre-ft) 5.52 172.54 6.27

C & E Loss (ft) 0.00 Cum SA (acres) 3.44 29.95 3.54

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: Divided flow computed for this cross-section.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 380

 

INPUT

Description:

Station Elevation Data num= 10

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1001794.344 1001784.344 116.751784.009 133.51784.344 133.51794.344

136.51794.344 136.51784.344 153.251784.009 1701784.344 1701794.344

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

100 .025 100 .015 170 .025

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

100 170 170 170.96 173 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1793.93 Element Left OB Channel Right OB

Vel Head (ft) 3.25 Wt. n-Val. 0.015

W.S. Elev (ft) 1790.68 Reach Len. (ft) 170.00 170.96 173.00

Crit W.S. (ft) 1790.68 Flow Area (sq ft) 435.42

E.G. Slope (ft/ft) 0.002698 Area (sq ft) 435.42

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 67.00 Top Width (ft) 67.00

Vel Total (ft/s) 14.47 Avg. Vel. (ft/s) 14.47

Max Chl Dpth (ft) 6.67 Hydr. Depth (ft) 6.50

Conv. Total (cfs) 121290.3 Conv. (cfs) 121290.3

Length Wtd. (ft) 170.96 Wetted Per. (ft) 92.34

Min Ch El (ft) 1784.01 Shear (lb/sq ft) 0.79

Alpha 1.00 Stream Power (lb/ft s) 170.00 0.00 0.00

Frctn Loss (ft) 0.46 Cum Volume (acre-ft) 5.52 168.33 6.27

C & E Loss (ft) 0.00 Cum SA (acres) 3.44 29.30 3.54

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: Divided flow computed for this cross-section.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 370

 

INPUT

Description:

Station Elevation Data num= 10

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1001790.899 1001780.899 116.751780.564 133.51780.899 133.51790.899

136.51790.899 136.51780.899 153.251780.564 1701780.899 1701790.899

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

100 .025 100 .015 170 .025

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

100 170 222 232.15 238 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1790.48 Element Left OB Channel Right OB

Vel Head (ft) 3.25 Wt. n-Val. 0.015

W.S. Elev (ft) 1787.23 Reach Len. (ft) 222.00 232.15 238.00

Crit W.S. (ft) 1787.23 Flow Area (sq ft) 435.43

E.G. Slope (ft/ft) 0.002698 Area (sq ft) 435.43

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 67.00 Top Width (ft) 67.00

Vel Total (ft/s) 14.47 Avg. Vel. (ft/s) 14.47

Max Chl Dpth (ft) 6.67 Hydr. Depth (ft) 6.50

Conv. Total (cfs) 121295.6 Conv. (cfs) 121295.6

Length Wtd. (ft) 232.15 Wetted Per. (ft) 92.34

Min Ch El (ft) 1780.56 Shear (lb/sq ft) 0.79

Alpha 1.00 Stream Power (lb/ft s) 170.00 0.00 0.00

Frctn Loss (ft) 0.63 Cum Volume (acre-ft) 5.52 166.62 6.27

C & E Loss (ft) 0.00 Cum SA (acres) 3.44 29.04 3.54

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: Divided flow computed for this cross-section.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 360

 

INPUT

Description:

Station Elevation Data num= 10

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

100 1789.74 100 1779.74 116.751779.405 133.5 1779.74 133.5 1789.74

136.5 1789.74 136.5 1779.74 153.251779.405 170 1779.74 170 1789.74

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

100 .025 100 .015 170 .025

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

100 170 323 314.29 310 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1789.32 Element Left OB Channel Right OB

Vel Head (ft) 3.25 Wt. n-Val. 0.015

W.S. Elev (ft) 1786.07 Reach Len. (ft) 323.00 314.29 310.00

Crit W.S. (ft) 1786.07 Flow Area (sq ft) 435.42

E.G. Slope (ft/ft) 0.002698 Area (sq ft) 435.42

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 67.00 Top Width (ft) 67.00

Vel Total (ft/s) 14.47 Avg. Vel. (ft/s) 14.47

Max Chl Dpth (ft) 6.67 Hydr. Depth (ft) 6.50

Conv. Total (cfs) 121290.3 Conv. (cfs) 121290.3

Length Wtd. (ft) 314.29 Wetted Per. (ft) 92.34

Min Ch El (ft) 1779.41 Shear (lb/sq ft) 0.79

Alpha 1.00 Stream Power (lb/ft s) 170.00 0.00 0.00

Frctn Loss (ft) 0.85 Cum Volume (acre-ft) 5.52 164.30 6.27

C & E Loss (ft) 0.00 Cum SA (acres) 3.44 28.68 3.54

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: Divided flow computed for this cross-section.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 350

 

INPUT

Description:

Station Elevation Data num= 10

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1001788.169 1001778.169 116.751777.834 133.51778.169 133.51788.169

136.51788.169 136.51778.169 153.251777.834 1701778.169 1701788.169

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

100 .025 100 .015 170 .025

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

100 170 439 436.71 435 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1787.75 Element Left OB Channel Right OB

Vel Head (ft) 3.25 Wt. n-Val. 0.015

W.S. Elev (ft) 1784.50 Reach Len. (ft) 439.00 436.71 435.00

Crit W.S. (ft) 1784.50 Flow Area (sq ft) 435.43

E.G. Slope (ft/ft) 0.002698 Area (sq ft) 435.43

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 67.00 Top Width (ft) 67.00

Vel Total (ft/s) 14.47 Avg. Vel. (ft/s) 14.47

Max Chl Dpth (ft) 6.67 Hydr. Depth (ft) 6.50

Conv. Total (cfs) 121293.7 Conv. (cfs) 121293.7

Length Wtd. (ft) 436.71 Wetted Per. (ft) 92.34

Min Ch El (ft) 1777.83 Shear (lb/sq ft) 0.79

Alpha 1.00 Stream Power (lb/ft s) 170.00 0.00 0.00

Frctn Loss (ft) 0.70 Cum Volume (acre-ft) 5.52 161.16 6.27

C & E Loss (ft) 0.38 Cum SA (acres) 3.44 28.20 3.54

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: Divided flow computed for this cross-section.

Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections.

Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4.

This may indicate the need for additional cross sections.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 340

 

INPUT

Description:

Station Elevation Data num= 5

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1001786.349 1001776.349 1351775.649 1701776.349 1701786.349

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

100 .025 100 .015 170 .025

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

100 170 85 85 85 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1785.96 Element Left OB Channel Right OB

Vel Head (ft) 1.97 Wt. n-Val. 0.015

W.S. Elev (ft) 1783.98 Reach Len. (ft) 85.00 85.00 85.00

Crit W.S. (ft) Flow Area (sq ft) 558.93

E.G. Slope (ft/ft) 0.001056 Area (sq ft) 558.93

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 70.00 Top Width (ft) 70.00

Vel Total (ft/s) 11.27 Avg. Vel. (ft/s) 11.27

Max Chl Dpth (ft) 8.33 Hydr. Depth (ft) 7.98

Conv. Total (cfs) 193906.3 Conv. (cfs) 193906.3

Length Wtd. (ft) 85.00 Wetted Per. (ft) 85.28

Min Ch El (ft) 1775.65 Shear (lb/sq ft) 0.43

Alpha 1.00 Stream Power (lb/ft s) 170.00 0.00 0.00

Frctn Loss (ft) 0.07 Cum Volume (acre-ft) 5.52 156.17 6.27

C & E Loss (ft) 0.13 Cum SA (acres) 3.44 27.51 3.54

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 338

 

INPUT

Description:

Station Elevation Data num= 5

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

0 1784.5 0 1775.17 35 1775.17 70 1775.17 70 1784.5

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

0 .025 0 .015 70 .025

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

0 70 95 95 95 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1785.75 Element Left OB Channel Right OB

Vel Head (ft) 1.54 Wt. n-Val. 0.015

W.S. Elev (ft) 1784.21 Reach Len. (ft) 95.00 95.00 95.00

Crit W.S. (ft) Flow Area (sq ft) 633.10

E.G. Slope (ft/ft) 0.000728 Area (sq ft) 633.10

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 70.00 Top Width (ft) 70.00

Vel Total (ft/s) 9.95 Avg. Vel. (ft/s) 9.95

Max Chl Dpth (ft) 9.04 Hydr. Depth (ft) 9.04

Conv. Total (cfs) 233568.0 Conv. (cfs) 233568.0

Length Wtd. (ft) 95.00 Wetted Per. (ft) 88.09

Min Ch El (ft) 1775.17 Shear (lb/sq ft) 0.33

Alpha 1.00 Stream Power (lb/ft s) 70.00 0.00 0.00

Frctn Loss (ft) 0.05 Cum Volume (acre-ft) 5.52 155.01 6.27

C & E Loss (ft) 0.21 Cum SA (acres) 3.44 27.37 3.54

 

Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections.

Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4.

This may indicate the need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 337

 

INPUT

Description:

Station Elevation Data num= 8

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

-45 1784.9 0 1784 15 1774.8 51 1774.8 86 1774.8

102 1784 117 1784.3 142 1785

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

-45 .025 0 .015 102 .025

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

0 102 60 60 60 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1785.49 Element Left OB Channel Right OB

Vel Head (ft) 0.82 Wt. n-Val. 0.025 0.015 0.025

W.S. Elev (ft) 1784.67 Reach Len. (ft) 60.00 60.00 60.00

Crit W.S. (ft) Flow Area (sq ft) 11.17 863.99 10.20

E.G. Slope (ft/ft) 0.000333 Area (sq ft) 11.17 863.99 10.20

Q Total (cfs) 6300.00 Flow (cfs) 5.84 6288.53 5.63

Top Width (ft) 163.59 Top Width (ft) 33.43 102.00 28.16

Vel Total (ft/s) 7.12 Avg. Vel. (ft/s) 0.52 7.28 0.55

Max Chl Dpth (ft) 9.87 Hydr. Depth (ft) 0.33 8.47 0.36

Conv. Total (cfs) 344993.8 Conv. (cfs) 319.9 344365.8 308.2

Length Wtd. (ft) 60.00 Wetted Per. (ft) 33.43 107.05 28.17

Min Ch El (ft) 1774.80 Shear (lb/sq ft) 0.01 0.17 0.01

Alpha 1.04 Stream Power (lb/ft s) 142.00 0.00 0.00

Frctn Loss (ft) 0.05 Cum Volume (acre-ft) 5.51 153.38 6.26

C & E Loss (ft) 0.05 Cum SA (acres) 3.40 27.19 3.51

 

Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4.

This may indicate the need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 335

 

INPUT

Description:

Station Elevation Data num= 5

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

100 1785.15 105 1775.15 140 1774.45 175 1775.15 180 1785.15

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

100 .035 100 .035 180 .035

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

100 180 40 40 40 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1785.40 Element Left OB Channel Right OB

Vel Head (ft) 1.29 Wt. n-Val. 0.035

W.S. Elev (ft) 1784.11 Reach Len. (ft) 40.00 40.00 40.00

Crit W.S. (ft) Flow Area (sq ft) 691.87

E.G. Slope (ft/ft) 0.003034 Area (sq ft) 691.87

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 78.96 Top Width (ft) 78.96

Vel Total (ft/s) 9.11 Avg. Vel. (ft/s) 9.11

Max Chl Dpth (ft) 9.66 Hydr. Depth (ft) 8.76

Conv. Total (cfs) 114369.9 Conv. (cfs) 114369.9

Length Wtd. (ft) 40.00 Wetted Per. (ft) 90.05

Min Ch El (ft) 1774.45 Shear (lb/sq ft) 1.46

Alpha 1.00 Stream Power (lb/ft s) 180.00 0.00 0.00

Frctn Loss (ft) 0.21 Cum Volume (acre-ft) 5.50 152.31 6.25

C & E Loss (ft) 0.10 Cum SA (acres) 3.38 27.06 3.49

 

Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections.

Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4.

This may indicate the need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 334

 

INPUT

Description:

Station Elevation Data num= 9

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

0 1783 20 1780 44 1778 52 1775 60 1774.4

85 1776 90 1779 105 1779.5 125 1786

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

0 .035 0 .035 125 .035

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

0 125 210 210 210 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1785.09 Element Left OB Channel Right OB

Vel Head (ft) 2.29 Wt. n-Val. 0.035

W.S. Elev (ft) 1782.79 Reach Len. (ft) 210.00 210.00 210.00

Crit W.S. (ft) 1782.79 Flow Area (sq ft) 518.26

E.G. Slope (ft/ft) 0.011144 Area (sq ft) 518.26

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 113.75 Top Width (ft) 113.75

Vel Total (ft/s) 12.16 Avg. Vel. (ft/s) 12.16

Max Chl Dpth (ft) 8.39 Hydr. Depth (ft) 4.56

Conv. Total (cfs) 59677.8 Conv. (cfs) 59677.8

Length Wtd. (ft) 210.00 Wetted Per. (ft) 116.02

Min Ch El (ft) 1774.40 Shear (lb/sq ft) 3.11

Alpha 1.00 Stream Power (lb/ft s) 125.00 0.00 0.00

Frctn Loss (ft) 2.34 Cum Volume (acre-ft) 5.50 151.75 6.25

C & E Loss (ft) 0.07 Cum SA (acres) 3.38 26.97 3.49

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 330

 

INPUT

Description:

Station Elevation Data num= 5

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1001783.549 1051773.549 1401772.849 1751773.549 1801783.549

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

100 .035 100 .035 180 .035

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

100 180 343.49 343.49 343.49 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1782.43 Element Left OB Channel Right OB

Vel Head (ft) 3.00 Wt. n-Val. 0.035

W.S. Elev (ft) 1779.43 Reach Len. (ft) 343.49 343.49 343.49

Crit W.S. (ft) 1779.43 Flow Area (sq ft) 453.31

E.G. Slope (ft/ft) 0.011170 Area (sq ft) 453.31

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 75.88 Top Width (ft) 75.88

Vel Total (ft/s) 13.90 Avg. Vel. (ft/s) 13.90

Max Chl Dpth (ft) 6.58 Hydr. Depth (ft) 5.97

Conv. Total (cfs) 59609.1 Conv. (cfs) 59609.1

Length Wtd. (ft) 343.49 Wetted Per. (ft) 83.16

Min Ch El (ft) 1772.85 Shear (lb/sq ft) 3.80

Alpha 1.00 Stream Power (lb/ft s) 180.00 0.00 0.00

Frctn Loss (ft) 1.45 Cum Volume (acre-ft) 5.50 149.41 6.25

C & E Loss (ft) 0.41 Cum SA (acres) 3.38 26.52 3.49

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections.

Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4.

This may indicate the need for additional cross sections.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 320

 

INPUT

Description:

Station Elevation Data num= 20

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1781.66 1022.01 1780.3 1022.11 1780.26 1030.73 1778.26 1039.26 1776.26

1047.79 1774.26 1052.67 1773.11 1061.45 1772.77 1063.83 1772.26 1067.59 1771.5

1104.76 1772.26 1107.08 1772.3 1112.55 1773.47 1130.75 1774.02 1131.67 1774.26

1139.29 1776.26 1146.67 1778.26 1153.84 1780.24 1155.09 1780.26 1191.2 1781.59

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1022.11 .02 1153.84 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1022.11 1153.84 489.89 489.1 487.69 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1780.55 Element Left OB Channel Right OB

Vel Head (ft) 1.62 Wt. n-Val. 0.020

W.S. Elev (ft) 1778.93 Reach Len. (ft) 489.89 489.10 487.69

Crit W.S. (ft) Flow Area (sq ft) 616.30

E.G. Slope (ft/ft) 0.002203 Area (sq ft) 616.30

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 121.21 Top Width (ft) 121.21

Vel Total (ft/s) 10.22 Avg. Vel. (ft/s) 10.22

Max Chl Dpth (ft) 7.43 Hydr. Depth (ft) 5.08

Conv. Total (cfs) 134214.1 Conv. (cfs) 134214.1

Length Wtd. (ft) 489.10 Wetted Per. (ft) 122.81

Min Ch El (ft) 1771.50 Shear (lb/sq ft) 0.69

Alpha 1.00 Stream Power (lb/ft s) 1191.20 0.00 0.00

Frctn Loss (ft) 0.21 Cum Volume (acre-ft) 5.50 145.19 6.25

C & E Loss (ft) 0.36 Cum SA (acres) 3.38 25.74 3.49

 

Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections.

Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4.

This may indicate the need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 310

 

INPUT

Description:

Station Elevation Data num= 20

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1779.06 1016.17 1778.26 1022.98 1777.94 1028.26 1776.26 1034.5 1774.26

1040.77 1772.26 1044.12 1771.21 1047.77 1770.26 1048.18 1770.13 1072.14 1770.04

1131.12 1770.06 1132.45 1770.26 1137.38 1771.05 1147.75 1770.88 1152.28 1772.26

1158.91 1774.26 1165.6 1776.26 1171.53 1778.03 1177.59 1778.26 1198.8 1779.06

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1022.98 .015 1171.53 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1022.98 1171.53 102.64 100.28 105.7 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1779.98 Element Left OB Channel Right OB

Vel Head (ft) 0.42 Wt. n-Val. 0.020 0.015 0.020

W.S. Elev (ft) 1779.56 Reach Len. (ft) 102.64 100.28 105.70

Crit W.S. (ft) Flow Area (sq ft) 24.42 1195.59 27.57

E.G. Slope (ft/ft) 0.000176 Area (sq ft) 24.42 1195.59 27.57

Q Total (cfs) 6300.00 Flow (cfs) 24.70 6248.25 27.05

Top Width (ft) 198.80 Top Width (ft) 22.98 148.55 27.27

Vel Total (ft/s) 5.05 Avg. Vel. (ft/s) 1.01 5.23 0.98

Max Chl Dpth (ft) 9.52 Hydr. Depth (ft) 1.06 8.05 1.01

Conv. Total (cfs) 474668.9 Conv. (cfs) 1860.9 470770.1 2037.9

Length Wtd. (ft) 100.33 Wetted Per. (ft) 23.50 150.87 27.79

Min Ch El (ft) 1770.04 Shear (lb/sq ft) 0.01 0.09 0.01

Alpha 1.06 Stream Power (lb/ft s) 1198.80 0.00 0.00

Frctn Loss (ft) 0.02 Cum Volume (acre-ft) 5.36 135.02 6.09

C & E Loss (ft) 0.01 Cum SA (acres) 3.25 24.22 3.34

 

Warning: The cross-section end points had to be extended vertically for the computed water surface.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 300

 

INPUT

Description:

Station Elevation Data num= 8

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1777.06 1017.87 1777.45 1025.54 1777.38 1025.54 1769.18 1128.56 1769.18

1128.56 1777.36 1133.94 1777.82 1147.13 1777.61

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1025.54 .015 1128.56 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1025.54 1128.56 102.54 102.75 98.55 .1 .3

Ineffective Flow num= 2

Sta L Sta R Elev Permanent

1000 1025.54 1777.38 F

1128.56 1147.13 1777.36 F

Blocked Obstructions num= 2

Sta L Sta R Elev Sta L Sta R Elev

1000 1025.54 1777.45 1128.56 1147.13 1777.82

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1779.95 Element Left OB Channel Right OB

Vel Head (ft) 0.52 Wt. n-Val. 0.020 0.015 0.020

W.S. Elev (ft) 1779.43 Reach Len. (ft) 0.10 0.10 0.10

Crit W.S. (ft) 1774.07 Flow Area (sq ft) 50.43 1055.40 29.80

E.G. Slope (ft/ft) 0.000192 Area (sq ft) 50.43 1055.40 29.80

Q Total (cfs) 6300.00 Flow (cfs) 77.86 6182.30 39.84

Top Width (ft) 147.13 Top Width (ft) 25.54 103.02 18.57

Vel Total (ft/s) 5.55 Avg. Vel. (ft/s) 1.54 5.86 1.34

Max Chl Dpth (ft) 10.24 Hydr. Depth (ft) 1.97 10.24 1.60

Conv. Total (cfs) 454121.8 Conv. (cfs) 5612.3 445638.0 2871.6

Length Wtd. (ft) 0.10 Wetted Per. (ft) 27.51 119.93 20.17

Min Ch El (ft) 1769.18 Shear (lb/sq ft) 0.02 0.11 0.02

Alpha 1.10 Stream Power (lb/ft s) 1147.13 0.00 0.00

Frctn Loss (ft) Cum Volume (acre-ft) 5.28 132.43 6.03

C & E Loss (ft) Cum SA (acres) 3.19 23.94 3.28

 

Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used.

 

BRIDGE

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 295

 

INPUT

Description: Bridge #2

 

Distance from Upstream XS = .1

Deck/Roadway Width = 102.55

Weir Coefficient = 2.6

Upstream Deck/Roadway Coordinates

num= 6

Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord

1000 1779.18 1768.81 1025.54 1779.18 1768.81 1025.54 1779.18 1775.18

1128.56 1779.18 1775.18 1128.56 1779.18 1768.81 1147.13 1779.18 1768.81

 

Upstream Bridge Cross Section Data

Station Elevation Data num= 8

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1777.06 1017.87 1777.45 1025.54 1777.38 1025.54 1769.18 1128.56 1769.18

1128.56 1777.36 1133.94 1777.82 1147.13 1777.61

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1025.54 .015 1128.56 .02

 

Bank Sta: Left Right Coeff Contr. Expan.

1025.54 1128.56 .1 .3

Ineffective Flow num= 2

Sta L Sta R Elev Permanent

1000 1025.54 1777.38 F

1128.56 1147.13 1777.36 F

Blocked Obstructions num= 2

Sta L Sta R Elev Sta L Sta R Elev

1000 1025.54 1777.45 1128.56 1147.13 1777.82

 

Downstream Deck/Roadway Coordinates

num= 5

Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord

1000 1779.18 1768.81 1047.98 1779.18 1768.81 1047.98 1779.18 1775.18

1147.13 1779.18 1775.18 1151 1779.18 1775.18

 

Downstream Bridge Cross Section Data

Station Elevation Data num= 7

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1777.86 1036.02 1777.31 1047.98 1776.26 1047.98 1768.81 1151 1768.81

1151 1776.26 1160.59 1777.03

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1047.98 .015 1151 .02

 

Bank Sta: Left Right Coeff Contr. Expan.

1047.98 1151 .1 .3

Ineffective Flow num= 2

Sta L Sta R Elev Permanent

1000 1047.98 1776.26 F

1151 1160.59 1776.26 F

Blocked Obstructions num= 2

Sta L Sta R Elev Sta L Sta R Elev

1000 1047.98 1777.26 1150.91 1160.59 1777.26

 

Upstream Embankment side slope = 0 horiz. to 1.0 vertical

Downstream Embankment side slope = 0 horiz. to 1.0 vertical

Maximum allowable submergence for weir flow = .95

Elevation at which weir flow begins = 1779.18

Energy head used in spillway design =

Spillway height used in design =

Weir crest shape = Broad Crested

 

Number of Piers = 8

 

Pier Data

Pier Station Upstream= 1036.35 Downstream= 1058.79

Upstream num= 2

Width Elev Width Elev

1.6275 1769.18 1.6275 1775.18

Downstream num= 2

Width Elev Width Elev

1.6275 1768.81 1.6275 1775.18

 

Pier Data

Pier Station Upstream= 1047.98 Downstream= 1070.42

Upstream num= 2

Width Elev Width Elev

1.628 1769.18 1.628 1775.18

Downstream num= 2

Width Elev Width Elev

1.628 1768.81 1.628 1775.18

 

Pier Data

Pier Station Upstream= 1059.61 Downstream= 1082.05

Upstream num= 2

Width Elev Width Elev

1.628 1769.18 1.628 1775.18

Downstream num= 2

Width Elev Width Elev

1.628 1768.81 1.628 1775.18

 

Pier Data

Pier Station Upstream= 1071.24 Downstream= 1093.68

Upstream num= 2

Width Elev Width Elev

1.628 1769.18 1.628 1775.18

Downstream num= 2

Width Elev Width Elev

1.628 1768.81 1.628 1775.18

 

Pier Data

Pier Station Upstream= 1082.86 Downstream= 1105.3

Upstream num= 2

Width Elev Width Elev

1.628 1769.18 1.628 1775.18

Downstream num= 2

Width Elev Width Elev

1.628 1768.81 1.628 1775.18

 

Pier Data

Pier Station Upstream= 1094.49 Downstream= 1116.93

Upstream num= 2

Width Elev Width Elev

1.628 1769.18 1.628 1775.18

Downstream num= 2

Width Elev Width Elev

1.628 1768.81 1.628 1775.18

 

Pier Data

Pier Station Upstream= 1106.12 Downstream= 1128.56

Upstream num= 2

Width Elev Width Elev

1.628 1769.18 1.628 1775.18

Downstream num= 2

Width Elev Width Elev

1.628 1768.81 1.628 1775.18

 

Pier Data

Pier Station Upstream= 1117.75 Downstream= 1140.19

Upstream num= 2

Width Elev Width Elev

1.628 1769.18 1.628 1775.18

Downstream num= 2

Width Elev Width Elev

1.628 1768.81 1.628 1775.18

 

Number of Bridge Coefficient Sets = 1

 

Low Flow Methods and Data

Yarnell KVal = .9

Selected Low Flow Methods = Yarnell

 

High Flow Method

Pressure and Weir flow

Submerged Inlet Cd =

Submerged Inlet + Outlet Cd = .8

Max Low Cord =

 

Additional Bridge Parameters

Add Friction component to Momentum

Do not add Weight component to Momentum

Class B flow critical depth computations use critical depth

inside the bridge at the upstream end

Criteria to check for pressure flow = Upstream energy grade line

 

BRIDGE OUTPUT Profile #PF 1

E.G. US. (ft) 1779.95 Element Inside BR US Inside BR DS

W.S. US. (ft) 1779.43 E.G. Elev (ft) 1779.95 1779.80

Q Total (cfs) 6300.00 W.S. Elev (ft) 1779.43 1779.43

Q Bridge (cfs) 6039.50 Crit W.S. (ft) 1774.53 1774.17

Q Weir (cfs) 260.50 Max Chl Dpth (ft) 10.24 10.61

Weir Sta Lft (ft) 1000.00 Vel Total (ft/s) 9.65 8.82

Weir Sta Rgt (ft) 1147.13 Flow Area (sq ft) 652.99 714.46

Weir Submerg 0.00 Froude # Chl 0.61 0.55

Weir Max Depth (ft) 0.77 Specif Force (cu ft) 6080.56 6263.25

Min El Weir Flow (ft) 1779.19 Hydr Depth (ft) 4.44 4.45

Min El Prs (ft) 1775.18 W.P. Total (ft) 435.61 459.39

Delta EG (ft) 3.82 Conv. Total (cfs)

Delta WS (ft) 5.72 Top Width (ft) 147.13 160.59

BR Open Area (sq ft) 539.98 Frctn Loss (ft)

BR Open Vel (ft/s) 11.18 C & E Loss (ft)

Coef of Q Shear Total (lb/sq ft)

Br Sel Method Press/Weir Power Total (lb/ft s) 1000.00 1000.00

 

Warning: Pier drag coefficient of 2.0 assumed for Class B flow.

Note: Yarnell answer is not valid if the water surface is above the low chord or if there is weir flow. The Yarnell answer has

been disregarded.

Note: Momentum answer is not valid if the water surface is above the low chord or if there is weir flow. The momentum

answer has been disregarded.

Note: The downstream water surface is below the minimum elevation for pressure flow. The sluice gate equations were used

for pressure flow.

Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used.

Note: For the cross section inside the bridge at the upstream end, the water surface and energy have been projected from

the upstream cross section. The selected bridge modeling method does not compute answers inside the bridge.

Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used.

Note: For the cross section inside the bridge at the downstream end, the energy is based on critical depth over the weir. The

water surface has been projected.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 290

 

INPUT

Description:

Station Elevation Data num= 7

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1777.86 1036.02 1777.31 1047.98 1776.26 1047.98 1768.81 1151 1768.81

1151 1776.26 1160.59 1777.03

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1047.98 .015 1151 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1047.98 1151 14.68 14.95 12.7 .1 .3

Ineffective Flow num= 2

Sta L Sta R Elev Permanent

1000 1047.98 1776.26 F

1151 1160.59 1776.26 F

Blocked Obstructions num= 2

Sta L Sta R Elev Sta L Sta R Elev

1000 1047.98 1777.26 1150.91 1160.59 1777.26

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1776.13 Element Left OB Channel Right OB

Vel Head (ft) 2.43 Wt. n-Val. 0.015

W.S. Elev (ft) 1773.71 Reach Len. (ft) 14.68 14.95 12.70

Crit W.S. (ft) 1773.71 Flow Area (sq ft) 503.95

E.G. Slope (ft/ft) 0.002162 Area (sq ft) 503.95

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 102.93 Top Width (ft) 102.93

Vel Total (ft/s) 12.50 Avg. Vel. (ft/s) 12.50

Max Chl Dpth (ft) 4.90 Hydr. Depth (ft) 4.90

Conv. Total (cfs) 135478.4 Conv. (cfs) 135478.4

Length Wtd. (ft) 14.95 Wetted Per. (ft) 112.72

Min Ch El (ft) 1768.81 Shear (lb/sq ft) 0.60

Alpha 1.00 Stream Power (lb/ft s) 1160.59 0.00 0.00

Frctn Loss (ft) 0.03 Cum Volume (acre-ft) 5.25 131.06 6.00

C & E Loss (ft) 0.00 Cum SA (acres) 3.11 23.69 3.25

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 280

 

INPUT

Description:

Station Elevation Data num= 18

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1778.06 1036.1 1777.28 1039.28 1776.26 1044.87 1774.63 1044.99 1774.26

1045.65 1772.26 1046.31 1770.26 1047.17 1768.26 1103.57 1768.26 1146.5 1768.44

1148.22 1768.26 1149.86 1768.26 1150.4 1770.26 1150.81 1772.26 1151.16 1774.26

1151.21 1774.46 1160.57 1776.29 1160.65 1776.26

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1044.87 .015 1151.21 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1044.87 1151.21 1 1 1 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1775.56 Element Left OB Channel Right OB

Vel Head (ft) 2.41 Wt. n-Val. 0.015

W.S. Elev (ft) 1773.14 Reach Len. (ft) 1.00 1.00 1.00

Crit W.S. (ft) 1773.14 Flow Area (sq ft) 505.21

E.G. Slope (ft/ft) 0.002150 Area (sq ft) 505.21

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 105.61 Top Width (ft) 105.61

Vel Total (ft/s) 12.47 Avg. Vel. (ft/s) 12.47

Max Chl Dpth (ft) 4.88 Hydr. Depth (ft) 4.78

Conv. Total (cfs) 135884.0 Conv. (cfs) 135884.0

Length Wtd. (ft) 1.00 Wetted Per. (ft) 112.93

Min Ch El (ft) 1768.26 Shear (lb/sq ft) 0.60

Alpha 1.00 Stream Power (lb/ft s) 1160.65 0.00 0.00

Frctn Loss (ft) 0.00 Cum Volume (acre-ft) 5.25 130.88 6.00

C & E Loss (ft) 0.00 Cum SA (acres) 3.11 23.66 3.25

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 270

 

INPUT

Description:

Station Elevation Data num= 20

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

964 1778.06 1000 1777.26 1003.1 1776.26 1008.92 1774.26 1008.94 1774.3

1009.59 1772.26 1010.24 1770.26 1010.83 1768.26 1011.18 1766.26 1011.54 1764.26

1113.08 1764.26 1114.49 1764.26 1114.56 1764.26 1114.95 1766.26 1115.24 1768.26

1115.55 1770.26 1115.92 1772.26 1116.05 1773.3 1122.67 1774.26 1132.66 1776.26

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

964 .02 1008.92 .015 1116.05 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1008.92 1116.05 33.84 21.92 8.99 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1771.54 Element Left OB Channel Right OB

Vel Head (ft) 2.43 Wt. n-Val. 0.015

W.S. Elev (ft) 1769.11 Reach Len. (ft) 33.84 21.92 8.99

Crit W.S. (ft) 1769.11 Flow Area (sq ft) 503.93

E.G. Slope (ft/ft) 0.002167 Area (sq ft) 503.93

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 104.79 Top Width (ft) 104.79

Vel Total (ft/s) 12.50 Avg. Vel. (ft/s) 12.50

Max Chl Dpth (ft) 4.85 Hydr. Depth (ft) 4.81

Conv. Total (cfs) 135338.4 Conv. (cfs) 135338.4

Length Wtd. (ft) 21.92 Wetted Per. (ft) 112.89

Min Ch El (ft) 1764.26 Shear (lb/sq ft) 0.60

Alpha 1.00 Stream Power (lb/ft s) 1132.66 0.00 0.00

Frctn Loss (ft) 0.05 Cum Volume (acre-ft) 5.25 130.87 6.00

C & E Loss (ft) 0.09 Cum SA (acres) 3.11 23.65 3.25

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 260

 

INPUT

Description:

Station Elevation Data num= 20

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1777.66 1020.49 1777.5 1022.9 1776.26 1026.35 1774.26 1029.81 1772.26

1033.31 1770.26 1042.07 1769.56 1048.18 1768.26 1050.85 1766.26 1051.85 1764.26

1154.61 1764.26 1155.13 1766.26 1155.64 1768.26 1171.52 1768.92 1173.98 1770.08

1174.12 1770.26 1176.75 1772.26 1179.4 1774.26 1183.08 1776.26 1187.74 1778.26

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1033.31 .015 1171.52 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1033.31 1171.52 1 1 1 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1771.38 Element Left OB Channel Right OB

Vel Head (ft) 2.13 Wt. n-Val. 0.015 0.020

W.S. Elev (ft) 1769.25 Reach Len. (ft) 1.00 1.00 1.00

Crit W.S. (ft) 1769.25 Flow Area (sq ft) 537.85 0.11

E.G. Slope (ft/ft) 0.002172 Area (sq ft) 537.85 0.11

Q Total (cfs) 6300.00 Flow (cfs) 6299.89 0.11

Top Width (ft) 128.69 Top Width (ft) 127.99 0.70

Vel Total (ft/s) 11.71 Avg. Vel. (ft/s) 11.71 0.97

Max Chl Dpth (ft) 4.99 Hydr. Depth (ft) 4.20 0.16

Conv. Total (cfs) 135169.6 Conv. (cfs) 135167.2 2.4

Length Wtd. (ft) 1.00 Wetted Per. (ft) 133.11 0.77

Min Ch El (ft) 1764.26 Shear (lb/sq ft) 0.55 0.02

Alpha 1.00 Stream Power (lb/ft s) 1187.74 0.00 0.00

Frctn Loss (ft) 0.00 Cum Volume (acre-ft) 5.25 130.61 6.00

C & E Loss (ft) 0.02 Cum SA (acres) 3.11 23.60 3.25

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 250

 

INPUT

Description:

Station Elevation Data num= 24

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1777.66 1020.11 1777.49 1022.51 1776.26 1025.97 1774.26 1029.5 1772.26

1033.08 1770.26 1036.04 1768.76 1037.59 1768.26 1043.3 1766.26 1047.58 1764.26

1050.92 1762.26 1053.04 1760.26 1154.39 1760.6 1154.67 1762.26 1155.12 1764.26

1155.69 1766.26 1162.7 1768.26 1171.85 1768.93 1174.97 1770.26 1178.13 1772.26

1180.86 1774.26 1183.9 1776.26 1187.8 1778.26 1190.22 1779.25

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1036.04 .015 1171.85 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1036.04 1171.85 57.45 58.6 58.44 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1767.65 Element Left OB Channel Right OB

Vel Head (ft) 2.35 Wt. n-Val. 0.015

W.S. Elev (ft) 1765.30 Reach Len. (ft) 57.45 58.60 58.44

Crit W.S. (ft) 1765.30 Flow Area (sq ft) 512.06

E.G. Slope (ft/ft) 0.002116 Area (sq ft) 512.06

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 110.06 Top Width (ft) 110.06

Vel Total (ft/s) 12.30 Avg. Vel. (ft/s) 12.30

Max Chl Dpth (ft) 5.04 Hydr. Depth (ft) 4.65

Conv. Total (cfs) 136953.5 Conv. (cfs) 136953.5

Length Wtd. (ft) 58.60 Wetted Per. (ft) 115.42

Min Ch El (ft) 1760.26 Shear (lb/sq ft) 0.59

Alpha 1.00 Stream Power (lb/ft s) 1190.22 0.00 0.00

Frctn Loss (ft) 0.16 Cum Volume (acre-ft) 5.25 130.60 6.00

C & E Loss (ft) 0.03 Cum SA (acres) 3.11 23.59 3.25

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 240

 

INPUT

Description:

Station Elevation Data num= 29

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1777.06 1026.08 1776.6 1026.81 1776.26 1030.67 1774.26 1034.53 1772.26

1038.38 1770.26 1042.19 1768.26 1045.88 1766.26 1049.77 1764.26 1053.67 1762.26

1057.57 1760.26 1059.06 1759.69 1143.57 1760.05 1145.62 1760.26 1152.68 1761

1157.83 1761.46 1159.46 1762.26 1163.99 1764.26 1168.57 1766.26 1173.21 1768.26

1177.84 1770.26 1181.98 1772.26 1185.85 1774.26 1189.72 1776.26 1193.59 1778.26

1194.47 1778.66 1267.84 1779.13 1276.18 1778.26 1280.88 1777.75

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1026.08 .02 1194.47 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1026.08 1194.47 496.31 492 488.69 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1767.14 Element Left OB Channel Right OB

Vel Head (ft) 2.24 Wt. n-Val. 0.020

W.S. Elev (ft) 1764.89 Reach Len. (ft) 496.31 492.00 488.69

Crit W.S. (ft) 1764.89 Flow Area (sq ft) 524.20

E.G. Slope (ft/ft) 0.003621 Area (sq ft) 524.20

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 116.90 Top Width (ft) 116.90

Vel Total (ft/s) 12.02 Avg. Vel. (ft/s) 12.02

Max Chl Dpth (ft) 5.20 Hydr. Depth (ft) 4.48

Conv. Total (cfs) 104694.6 Conv. (cfs) 104694.6

Length Wtd. (ft) 492.00 Wetted Per. (ft) 118.93

Min Ch El (ft) 1759.69 Shear (lb/sq ft) 1.00

Alpha 1.00 Stream Power (lb/ft s) 1280.88 0.00 0.00

Frctn Loss (ft) 1.74 Cum Volume (acre-ft) 5.25 129.90 6.00

C & E Loss (ft) 0.05 Cum SA (acres) 3.11 23.44 3.25

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 230

 

INPUT

Description:

Station Elevation Data num= 28

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1765.86 1034.85 1765.62 1040.25 1764.26 1043.65 1763.39 1056.95 1762.57

1057.18 1762.26 1062.98 1760.26 1068.2 1758.26 1073.41 1756.26 1074.65 1755.79

1090.81 1754.86 1093.04 1754.26 1100.45 1752.38 1113.46 1752.38 1119.83 1753.75

1124.28 1754.26 1136.24 1755.52 1137.93 1756.26 1142.51 1758.26 1147.1 1760.26

1151.69 1762.26 1156.15 1764.2 1156.82 1764.26 1168.26 1766.01 1169.03 1766.26

1176.57 1768.26 1178.93 1768.9 1205.52 1769.12

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1034.85 .02 1169.03 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1034.85 1169.03 490.46 494.76 498.91 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1763.45 Element Left OB Channel Right OB

Vel Head (ft) 2.74 Wt. n-Val. 0.020

W.S. Elev (ft) 1760.70 Reach Len. (ft) 490.46 494.76 498.91

Crit W.S. (ft) 1760.70 Flow Area (sq ft) 473.88

E.G. Slope (ft/ft) 0.003443 Area (sq ft) 473.88

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 86.42 Top Width (ft) 86.42

Vel Total (ft/s) 13.29 Avg. Vel. (ft/s) 13.29

Max Chl Dpth (ft) 8.32 Hydr. Depth (ft) 5.48

Conv. Total (cfs) 107365.3 Conv. (cfs) 107365.3

Length Wtd. (ft) 494.76 Wetted Per. (ft) 88.99

Min Ch El (ft) 1752.38 Shear (lb/sq ft) 1.14

Alpha 1.00 Stream Power (lb/ft s) 1205.52 0.00 0.00

Frctn Loss (ft) 1.72 Cum Volume (acre-ft) 5.25 124.27 6.00

C & E Loss (ft) 0.03 Cum SA (acres) 3.11 22.29 3.25

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 220

 

INPUT

Description:

Station Elevation Data num= 26

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1761.96 1041.51 1762.09 1045.1 1760.26 1049.03 1758.26 1052.95 1756.26

1056.86 1754.26 1060.75 1752.26 1064.59 1750.26 1066.03 1749.51 1087.16 1748.41

1087.54 1748.26 1092.6 1746.44 1106.98 1746.26 1109.94 1746.26 1110.03 1746.22

1113.56 1748.06 1116.26 1748.26 1139.68 1750.26 1139.83 1750.25 1144.13 1752.26

1148.41 1754.26 1152.7 1756.26 1156.99 1758.26 1160.79 1760.03 1173.7 1760.26

1199.32 1760.56

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1041.51 .02 1160.79 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1041.51 1160.79 464.69 476.72 489.34 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1756.87 Element Left OB Channel Right OB

Vel Head (ft) 2.64 Wt. n-Val. 0.020

W.S. Elev (ft) 1754.23 Reach Len. (ft) 464.69 476.72 489.34

Crit W.S. (ft) 1754.23 Flow Area (sq ft) 482.88

E.G. Slope (ft/ft) 0.003498 Area (sq ft) 482.88

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 91.43 Top Width (ft) 91.43

Vel Total (ft/s) 13.05 Avg. Vel. (ft/s) 13.05

Max Chl Dpth (ft) 8.01 Hydr. Depth (ft) 5.28

Conv. Total (cfs) 106513.0 Conv. (cfs) 106513.0

Length Wtd. (ft) 476.72 Wetted Per. (ft) 94.39

Min Ch El (ft) 1746.22 Shear (lb/sq ft) 1.12

Alpha 1.00 Stream Power (lb/ft s) 1199.32 0.00 0.00

Frctn Loss (ft) 1.66 Cum Volume (acre-ft) 5.25 118.83 6.00

C & E Loss (ft) 0.02 Cum SA (acres) 3.11 21.28 3.25

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 210

 

INPUT

Description:

Station Elevation Data num= 25

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

951.7 1754.26 1000 1754.26 1005.42 1752.26 1010.97 1750.26 1016.52 1748.26

1022.03 1746.26 1027.65 1744.26 1028.59 1743.92 1037.62 1742.76 1039.36 1742.26

1047.1 1740.26 1048.91 1739.78 1061.69 1740.06 1062.13 1740.26 1067.4 1742.26

1071.1 1743.46 1079.44 1744.26 1088.66 1745.15 1091.26 1746.26 1095.98 1748.26

1100.7 1750.26 1105.41 1752.26 1110.13 1754.26 1113.22 1755.57 1141.88 1755.47

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

951.7 .02 1000 .02 1113.22 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1000 1113.22 499.74 500.38 500.05 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1751.94 Element Left OB Channel Right OB

Vel Head (ft) 2.81 Wt. n-Val. 0.020

W.S. Elev (ft) 1749.13 Reach Len. (ft) 499.74 500.38 500.05

Crit W.S. (ft) 1749.13 Flow Area (sq ft) 468.30

E.G. Slope (ft/ft) 0.003463 Area (sq ft) 468.30

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 83.90 Top Width (ft) 83.90

Vel Total (ft/s) 13.45 Avg. Vel. (ft/s) 13.45

Max Chl Dpth (ft) 9.34 Hydr. Depth (ft) 5.58

Conv. Total (cfs) 107059.3 Conv. (cfs) 107059.3

Length Wtd. (ft) 500.38 Wetted Per. (ft) 86.76

Min Ch El (ft) 1739.78 Shear (lb/sq ft) 1.17

Alpha 1.00 Stream Power (lb/ft s) 1141.88 0.00 0.00

Frctn Loss (ft) 1.75 Cum Volume (acre-ft) 5.25 113.63 6.00

C & E Loss (ft) 0.12 Cum SA (acres) 3.11 20.32 3.25

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 200

 

INPUT

Description:

Station Elevation Data num= 22

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

956.38 1751.06 992.25 1750.26 995.39 1750.1 1000 1748.26 1004.98 1746.26

1009.94 1744.26 1014.87 1742.26 1019.77 1740.26 1020.02 1740.16 1027.73 1739.78

1037.66 1738.96 1061.55 1738.96 1074.9 1740.02 1083.37 1740.26 1103 1740.75

1106.13 1742.26 1110.31 1744.26 1114.5 1746.26 1118.68 1748.26 1122.87 1750.26

1123.7 1750.66 1144.3 1750.62

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

956.38 .02 1000 .02 1122.87 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1000 1122.87 494.16 495.37 496.56 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1747.57 Element Left OB Channel Right OB

Vel Head (ft) 2.42 Wt. n-Val. 0.020

W.S. Elev (ft) 1745.15 Reach Len. (ft) 494.16 495.37 496.56

Crit W.S. (ft) 1745.15 Flow Area (sq ft) 504.83

E.G. Slope (ft/ft) 0.003543 Area (sq ft) 504.83

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 104.43 Top Width (ft) 104.43

Vel Total (ft/s) 12.48 Avg. Vel. (ft/s) 12.48

Max Chl Dpth (ft) 6.19 Hydr. Depth (ft) 4.83

Conv. Total (cfs) 105840.7 Conv. (cfs) 105840.7

Length Wtd. (ft) 495.37 Wetted Per. (ft) 106.50

Min Ch El (ft) 1738.96 Shear (lb/sq ft) 1.05

Alpha 1.00 Stream Power (lb/ft s) 1144.30 0.00 0.00

Frctn Loss (ft) 1.76 Cum Volume (acre-ft) 5.25 108.04 6.00

C & E Loss (ft) 0.02 Cum SA (acres) 3.11 19.24 3.25

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 190

 

INPUT

Description:

Station Elevation Data num= 22

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

950.33 1745.76 998.69 1744.72 1000 1744.26 1005.6 1742.26 1011 1740.26

1016.29 1738.26 1018.97 1737.49 1040.24 1736.76 1042.17 1736.26 1046.61 1735.05

1078.44 1735.16 1082 1736.26 1084.43 1736.97 1101.82 1738.26 1105.68 1738.56

1110.9 1740.26 1116.85 1742.26 1121.49 1743.89 1135.5 1744.26 1142.58 1744.5

1143.57 1744.26 1144.92 1743.9

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

950.33 .02 1000 .02 1121.49 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1000 1121.49 499.18 497.74 497.1 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1744.14 Element Left OB Channel Right OB

Vel Head (ft) 2.36 Wt. n-Val. 0.020

W.S. Elev (ft) 1741.78 Reach Len. (ft) 499.18 497.74 497.10

Crit W.S. (ft) 1741.78 Flow Area (sq ft) 511.36

E.G. Slope (ft/ft) 0.003560 Area (sq ft) 511.36

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 108.54 Top Width (ft) 108.54

Vel Total (ft/s) 12.32 Avg. Vel. (ft/s) 12.32

Max Chl Dpth (ft) 6.73 Hydr. Depth (ft) 4.71

Conv. Total (cfs) 105589.9 Conv. (cfs) 105589.9

Length Wtd. (ft) 497.74 Wetted Per. (ft) 110.37

Min Ch El (ft) 1735.05 Shear (lb/sq ft) 1.03

Alpha 1.00 Stream Power (lb/ft s) 1144.92 0.00 0.00

Frctn Loss (ft) 1.71 Cum Volume (acre-ft) 5.25 102.26 6.00

C & E Loss (ft) 0.11 Cum SA (acres) 3.11 18.03 3.25

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 180

 

INPUT

Description:

Station Elevation Data num= 19

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1740.66 1017.86 1740.26 1037.9 1738.84 1039.45 1738.26 1044.91 1736.26

1050.47 1734.26 1055.47 1732.48 1062.62 1732.68 1097.25 1732.26 1099.77 1731.86

1119.42 1732.26 1121.41 1732.3 1155.75 1733.41 1158.51 1734.26 1165.22 1736.26

1172.22 1738.26 1178.31 1739.98 1187.42 1740.26 1197.86 1740.53

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1037.9 .02 1178.31 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1037.9 1178.31 490.6 491.83 492.37 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1739.44 Element Left OB Channel Right OB

Vel Head (ft) 2.00 Wt. n-Val. 0.020

W.S. Elev (ft) 1737.44 Reach Len. (ft) 490.60 491.83 492.37

Crit W.S. (ft) 1737.29 Flow Area (sq ft) 555.38

E.G. Slope (ft/ft) 0.003334 Area (sq ft) 555.38

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 127.67 Top Width (ft) 127.67

Vel Total (ft/s) 11.34 Avg. Vel. (ft/s) 11.34

Max Chl Dpth (ft) 5.58 Hydr. Depth (ft) 4.35

Conv. Total (cfs) 109100.3 Conv. (cfs) 109100.3

Length Wtd. (ft) 491.83 Wetted Per. (ft) 129.18

Min Ch El (ft) 1731.86 Shear (lb/sq ft) 0.90

Alpha 1.00 Stream Power (lb/ft s) 1197.86 0.00 0.00

Frctn Loss (ft) 1.72 Cum Volume (acre-ft) 5.25 96.16 6.00

C & E Loss (ft) 0.01 Cum SA (acres) 3.11 16.68 3.25

 

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 170

 

INPUT

Description:

Station Elevation Data num= 20

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1736.86 1003.78 1737.79 1042.95 1736.76 1044.42 1736.26 1050.31 1734.26

1056.26 1732.26 1060.18 1730.96 1095.07 1730.68 1097.52 1730.26 1099.65 1729.92

1123.92 1729.56 1128.46 1730.26 1140.57 1732.08 1146.01 1732.26 1167.12 1732.92

1172.19 1734.26 1179.55 1736.26 1183.42 1737.35 1201.5 1737.66 1203.33 1738.26

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1042.95 .02 1183.42 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1042.95 1183.42 486.67 487.26 487.82 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1737.71 Element Left OB Channel Right OB

Vel Head (ft) 2.08 Wt. n-Val. 0.020

W.S. Elev (ft) 1735.63 Reach Len. (ft) 486.67 487.26 487.82

Crit W.S. (ft) 1735.63 Flow Area (sq ft) 544.26

E.G. Slope (ft/ft) 0.003684 Area (sq ft) 544.26

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 130.94 Top Width (ft) 130.94

Vel Total (ft/s) 11.58 Avg. Vel. (ft/s) 11.58

Max Chl Dpth (ft) 6.07 Hydr. Depth (ft) 4.16

Conv. Total (cfs) 103801.6 Conv. (cfs) 103801.6

Length Wtd. (ft) 487.26 Wetted Per. (ft) 132.33

Min Ch El (ft) 1729.56 Shear (lb/sq ft) 0.95

Alpha 1.00 Stream Power (lb/ft s) 1203.33 0.00 0.00

Frctn Loss (ft) 1.18 Cum Volume (acre-ft) 5.25 89.96 6.00

C & E Loss (ft) 0.24 Cum SA (acres) 3.11 15.22 3.25

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections.

Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4.

This may indicate the need for additional cross sections.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 160

 

INPUT

Description:

Station Elevation Data num= 22

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1736.26 1002.52 1736.78 1015.73 1736.26 1042.38 1735.52 1045.87 1734.26

1051.46 1732.26 1057.16 1730.26 1058.29 1729.87 1089.49 1729.85 1097.9 1728.73

1115.47 1728.26 1127.39 1727.87 1131.14 1728.26 1145.07 1729.72 1162.54 1730.26

1169.98 1730.46 1173.77 1732.26 1178.13 1734.26 1181.15 1735.64 1195.86 1736.26

1200.57 1736.46 1203.67 1738.07

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1042.38 .02 1195.86 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1042.38 1195.86 501.43 501.51 502.7 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1736.27 Element Left OB Channel Right OB

Vel Head (ft) 1.27 Wt. n-Val. 0.020

W.S. Elev (ft) 1735.00 Reach Len. (ft) 501.43 501.51 502.70

Crit W.S. (ft) Flow Area (sq ft) 696.07

E.G. Slope (ft/ft) 0.001716 Area (sq ft) 696.07

Q Total (cfs) 6300.00 Flow (cfs) 6300.00

Top Width (ft) 135.91 Top Width (ft) 135.91

Vel Total (ft/s) 9.05 Avg. Vel. (ft/s) 9.05

Max Chl Dpth (ft) 7.13 Hydr. Depth (ft) 5.12

Conv. Total (cfs) 152105.1 Conv. (cfs) 152105.1

Length Wtd. (ft) 501.51 Wetted Per. (ft) 137.99

Min Ch El (ft) 1727.87 Shear (lb/sq ft) 0.54

Alpha 1.00 Stream Power (lb/ft s) 1203.67 0.00 0.00

Frctn Loss (ft) 0.57 Cum Volume (acre-ft) 5.25 83.02 6.00

C & E Loss (ft) 0.14 Cum SA (acres) 3.11 13.73 3.25

 

Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4.

This may indicate the need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 150

 

INPUT

Description:

Station Elevation Data num= 18

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1734.26 1018.39 1733.95 1024.12 1732.26 1030.88 1730.26 1035.9 1728.74

1066.83 1728.36 1067.43 1728.26 1074.87 1726.46 1083.96 1726.26 1107.26 1725.79

1108.86 1726.26 1113.02 1727.49 1135.88 1728.26 1136.31 1728.25 1142.71 1730.26

1149.03 1732.26 1152.46 1733.35 1169.72 1733.69

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1018.39 .02 1152.46 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1018.39 1152.46 491.39 489.94 488.88 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1735.56 Element Left OB Channel Right OB

Vel Head (ft) 0.81 Wt. n-Val. 0.020 0.020 0.020

W.S. Elev (ft) 1734.75 Reach Len. (ft) 491.39 489.94 488.88

Crit W.S. (ft) Flow Area (sq ft) 11.84 859.95 21.21

E.G. Slope (ft/ft) 0.000815 Area (sq ft) 11.84 859.95 21.21

Q Total (cfs) 6300.00 Flow (cfs) 18.39 6232.03 49.58

Top Width (ft) 169.72 Top Width (ft) 18.39 134.07 17.26

Vel Total (ft/s) 7.05 Avg. Vel. (ft/s) 1.55 7.25 2.34

Max Chl Dpth (ft) 8.96 Hydr. Depth (ft) 0.64 6.41 1.23

Conv. Total (cfs) 220740.0 Conv. (cfs) 644.4 218358.3 1737.3

Length Wtd. (ft) 489.99 Wetted Per. (ft) 18.88 136.11 18.32

Min Ch El (ft) 1725.79 Shear (lb/sq ft) 0.03 0.32 0.06

Alpha 1.04 Stream Power (lb/ft s) 1169.72 0.00 0.00

Frctn Loss (ft) 0.14 Cum Volume (acre-ft) 5.19 74.06 5.87

C & E Loss (ft) 0.14 Cum SA (acres) 3.00 12.17 3.15

 

Warning: The cross-section end points had to be extended vertically for the computed water surface.

Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4.

This may indicate the need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 140

 

INPUT

Description:

Station Elevation Data num= 13

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1731.76 1149.72 1730.67 1150.76 1730.26 1155.81 1728.26 1161.07 1726.26

1165.81 1725.06 1250.59 1724.86 1254.37 1726.26 1259.66 1728.26 1264.74 1730.26

1265.63 1730.56 1316.23 1731.06 1343.83 1730.44

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1149.72 .015 1265.63 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1149.72 1265.63 64.74 64.14 64.09 .1 .3

Ineffective Flow num= 2

Sta L Sta R Elev Permanent

1000 1149.72 1730.67 F

1265.63 1343.83 1730.56 F

Blocked Obstructions num= 2

Sta L Sta R Elev Sta L Sta R Elev

1000 1149.72 1732.26 1265.63 1343.83 1732.26

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1735.28 Element Left OB Channel Right OB

Vel Head (ft) 0.33 Wt. n-Val. 0.020 0.015 0.020

W.S. Elev (ft) 1734.94 Reach Len. (ft) 64.74 64.14 64.09

Crit W.S. (ft) 1730.23 Flow Area (sq ft) 401.79 1073.21 209.86

E.G. Slope (ft/ft) 0.000140 Area (sq ft) 401.79 1073.21 209.86

Q Total (cfs) 6400.00 Flow (cfs) 673.44 5378.54 348.02

Top Width (ft) 343.83 Top Width (ft) 149.72 115.91 78.20

Vel Total (ft/s) 3.80 Avg. Vel. (ft/s) 1.68 5.01 1.66

Max Chl Dpth (ft) 10.08 Hydr. Depth (ft) 2.68 9.26 2.68

Conv. Total (cfs) 541387.4 Conv. (cfs) 56967.8 454980.1 29439.5

Length Wtd. (ft) 64.17 Wetted Per. (ft) 152.40 121.22 80.88

Min Ch El (ft) 1724.86 Shear (lb/sq ft) 0.02 0.08 0.02

Alpha 1.49 Stream Power (lb/ft s) 1343.83 0.00 0.00

Frctn Loss (ft) 0.01 Cum Volume (acre-ft) 2.85 63.19 4.58

C & E Loss (ft) 0.02 Cum SA (acres) 2.05 10.77 2.61

 

Warning: The cross-section end points had to be extended vertically for the computed water surface.

Warning: The cross section had to be extended vertically during the critical depth calculations.

Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, energy was used.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 130

 

INPUT

Description:

Station Elevation Data num= 8

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1730.86 1018.83 1730.97 1035.81 1730.26 1035.81 1724.79 1142.81 1724.79

1142.81 1730.26 1157.29 1731.13 1174.35 1730.95

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1035.81 .015 1142.81 .02

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1035.81 1142.81 120.77 119.69 117.86 .1 .3

Ineffective Flow num= 2

Sta L Sta R Elev Permanent

1000 1035.81 1730.26 F

1142.81 1174.35 1730.26 F

Blocked Obstructions num= 2

Sta L Sta R Elev Sta L Sta R Elev

1000 1035.81 1733.26 1142.81 1174.35 1733.26

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1735.25 Element Left OB Channel Right OB

Vel Head (ft) 0.53 Wt. n-Val. 0.020 0.015 0.020

W.S. Elev (ft) 1734.72 Reach Len. (ft) 0.10 0.10 0.10

Crit W.S. (ft) 1729.61 Flow Area (sq ft) 52.19 1062.22 45.96

E.G. Slope (ft/ft) 0.000202 Area (sq ft) 52.19 1062.22 45.96

Q Total (cfs) 6400.00 Flow (cfs) 69.05 6270.35 60.60

Top Width (ft) 174.35 Top Width (ft) 35.81 107.00 31.54

Vel Total (ft/s) 5.52 Avg. Vel. (ft/s) 1.32 5.90 1.32

Max Chl Dpth (ft) 9.93 Hydr. Depth (ft) 1.46 9.93 1.46

Conv. Total (cfs) 449785.8 Conv. (cfs) 4852.8 440673.9 4259.1

Length Wtd. (ft) 0.10 Wetted Per. (ft) 37.27 123.94 33.00

Min Ch El (ft) 1724.79 Shear (lb/sq ft) 0.02 0.11 0.02

Alpha 1.12 Stream Power (lb/ft s) 1174.35 0.00 0.00

Frctn Loss (ft) Cum Volume (acre-ft) 2.52 61.62 4.39

C & E Loss (ft) Cum SA (acres) 1.91 10.60 2.53

 

Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used.

 

BRIDGE

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 125

 

INPUT

Description: Bridge #1

 

Distance from Upstream XS = .1

Deck/Roadway Width = 119.49

Weir Coefficient = 2.6

Upstream Deck/Roadway Coordinates

num= 6

Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord

1000 1733.69 1724.16 1035.81 1733.69 1724.16 1035.81 1733.69 1729.79

1142.81 1733.69 1729.79 1142.81 1733.69 1724.16 1174.35 1733.69 1724.16

 

Upstream Bridge Cross Section Data

Station Elevation Data num= 8

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1730.86 1018.83 1730.97 1035.81 1730.26 1035.81 1724.79 1142.81 1724.79

1142.81 1730.26 1157.29 1731.13 1174.35 1730.95

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .02 1035.81 .015 1142.81 .02

 

Bank Sta: Left Right Coeff Contr. Expan.

1035.81 1142.81 .1 .3

Ineffective Flow num= 2

Sta L Sta R Elev Permanent

1000 1035.81 1730.26 F

1142.81 1174.35 1730.26 F

Blocked Obstructions num= 2

Sta L Sta R Elev Sta L Sta R Elev

1000 1035.81 1733.26 1142.81 1174.35 1733.26

 

Downstream Deck/Roadway Coordinates

num= 6

Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord

1000 1733.69 1724.16 1029.49 1733.69 1724.16 1029.49 1733.69 1729.79

1136.49 1733.69 1729.79 1136.49 1733.69 1724.16 1174.35 1733.69 1724.16

 

Downstream Bridge Cross Section Data

Station Elevation Data num= 7

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1732.56 1006.09 1732.26 1029.49 1730.26 1029.49 1724.16 1136.49 1724.16

1136.49 1730.26 1146.34 1730.26

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .03 1029.49 .015 1136.49 .03

 

Bank Sta: Left Right Coeff Contr. Expan.

1029.49 1136.49 .1 .3

Ineffective Flow num= 2

Sta L Sta R Elev Permanent

1000 1029.49 1730.26 F

1136.49 1146.34 1730.26 F

Blocked Obstructions num= 2

Sta L Sta R Elev Sta L Sta R Elev

1000 1029.49 1732.26 1136.49 1146.34 1732.26

 

Upstream Embankment side slope = 0 horiz. to 1.0 vertical

Downstream Embankment side slope = 0 horiz. to 1.0 vertical

Maximum allowable submergence for weir flow = .95

Elevation at which weir flow begins = 1733.69

Energy head used in spillway design =

Spillway height used in design =

Weir crest shape = Broad Crested

 

Number of Piers = 1

 

Pier Data

Pier Station Upstream= 1089.31 Downstream= 1082.99

Upstream num= 2

Width Elev Width Elev

7 1724.79 7 1729.79

Downstream num= 2

Width Elev Width Elev

7 1724.16 7 1729.79

 

Number of Bridge Coefficient Sets = 1

 

Low Flow Methods and Data

Yarnell KVal = .9

Selected Low Flow Methods = Yarnell

 

High Flow Method

Pressure and Weir flow

Submerged Inlet Cd =

Submerged Inlet + Outlet Cd = .8

Max Low Cord =

 

Additional Bridge Parameters

Add Friction component to Momentum

Do not add Weight component to Momentum

Class B flow critical depth computations use critical depth

inside the bridge at the upstream end

Criteria to check for pressure flow = Upstream energy grade line

 

BRIDGE OUTPUT Profile #PF 1

E.G. US. (ft) 1735.25 Element Inside BR US Inside BR DS

W.S. US. (ft) 1734.72 E.G. Elev (ft) 1735.25 1735.16

Q Total (cfs) 6400.00 W.S. Elev (ft) 1734.72 1734.68

Q Bridge (cfs) 5663.65 Crit W.S. (ft) 1729.80 1729.20

Q Weir (cfs) 736.35 Max Chl Dpth (ft) 9.93 10.51

Weir Sta Lft (ft) 1000.00 Vel Total (ft/s) 8.29 8.09

Weir Sta Rgt (ft) 1146.34 Flow Area (sq ft) 771.63 791.00

Weir Submerg 0.00 Froude # Chl 0.54 0.51

Weir Max Depth (ft) 1.56 Specif Force (cu ft) 5727.52 6254.39

Min El Weir Flow (ft) 1733.70 Hydr Depth (ft) 4.43 5.41

Min El Prs (ft) 1729.79 W.P. Total (ft) 396.40 370.83

Delta EG (ft) 3.88 Conv. Total (cfs)

Delta WS (ft) 5.73 Top Width (ft) 174.35 146.34

BR Open Area (sq ft) 500.00 Frctn Loss (ft)

BR Open Vel (ft/s) 11.33 C & E Loss (ft)

Coef of Q Shear Total (lb/sq ft)

Br Sel Method Press/Weir Power Total (lb/ft s) 1000.00 1000.00

 

Note: Yarnell answer is not valid if the water surface is above the low chord or if there is weir flow. The Yarnell answer has

been disregarded.

Note: The downstream water surface is below the minimum elevation for pressure flow. The sluice gate equations were used

for pressure flow.

Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used.

Note: For the cross section inside the bridge at the upstream end, the water surface and energy have been projected from

the upstream cross section. The selected bridge modeling method does not compute answers inside the bridge.

Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used.

Note: For the cross section inside the bridge at the downstream end, the water surface and energy are based on critical

depth over the weir.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 120

 

INPUT

Description:

Station Elevation Data num= 7

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1732.56 1006.09 1732.26 1029.49 1730.26 1029.49 1724.16 1136.49 1724.16

1136.49 1730.26 1146.34 1730.26

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .03 1029.49 .015 1136.49 .03

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1029.49 1136.49 88.77 90.11 93.13 .1 .3

Ineffective Flow num= 2

Sta L Sta R Elev Permanent

1000 1029.49 1730.26 F

1136.49 1146.34 1730.26 F

Blocked Obstructions num= 2

Sta L Sta R Elev Sta L Sta R Elev

1000 1029.49 1732.26 1136.49 1146.34 1732.26

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1731.37 Element Left OB Channel Right OB

Vel Head (ft) 2.39 Wt. n-Val. 0.015

W.S. Elev (ft) 1728.98 Reach Len. (ft) 88.77 90.11 93.13

Crit W.S. (ft) 1728.98 Flow Area (sq ft) 516.19

E.G. Slope (ft/ft) 0.002156 Area (sq ft) 516.19

Q Total (cfs) 6400.00 Flow (cfs) 6400.00

Top Width (ft) 107.00 Top Width (ft) 107.00

Vel Total (ft/s) 12.40 Avg. Vel. (ft/s) 12.40

Max Chl Dpth (ft) 4.82 Hydr. Depth (ft) 4.82

Conv. Total (cfs) 137827.5 Conv. (cfs) 137827.5

Length Wtd. (ft) 90.11 Wetted Per. (ft) 116.65

Min Ch El (ft) 1724.16 Shear (lb/sq ft) 0.60

Alpha 1.00 Stream Power (lb/ft s) 1146.34 0.00 0.00

Frctn Loss (ft) 0.19 Cum Volume (acre-ft) 2.43 59.86 4.33

C & E Loss (ft) 0.00 Cum SA (acres) 1.82 10.31 2.48

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 110

 

INPUT

Description:

Station Elevation Data num= 21

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1734.76 1002.64 1734.26 1012.69 1732.26 1022.67 1730.26 1024.87 1729.82

1027.45 1728.26 1030.85 1726.26 1034.42 1724.26 1036.37 1722.76 1099.9 1722.76

1122.88 1722.76 1123.19 1722.76 1123.29 1722.76 1126.96 1724.26 1130.74 1726.26

1134.53 1728.26 1137.41 1729.78 1142.14 1730.26 1148.68 1731.31 1154.29 1732.26

1164.66 1733.96

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .03 1022.67 .015 1137.41 .03

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1022.67 1137.41 25.99 25.69 26.18 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1730.48 Element Left OB Channel Right OB

Vel Head (ft) 2.43 Wt. n-Val. 0.015

W.S. Elev (ft) 1728.05 Reach Len. (ft) 25.99 25.69 26.18

Crit W.S. (ft) 1728.05 Flow Area (sq ft) 511.37

E.G. Slope (ft/ft) 0.002034 Area (sq ft) 511.37

Q Total (cfs) 6400.00 Flow (cfs) 6400.00

Top Width (ft) 106.32 Top Width (ft) 106.32

Vel Total (ft/s) 12.52 Avg. Vel. (ft/s) 12.52

Max Chl Dpth (ft) 5.29 Hydr. Depth (ft) 4.81

Conv. Total (cfs) 141902.9 Conv. (cfs) 141902.9

Length Wtd. (ft) 25.69 Wetted Per. (ft) 109.07

Min Ch El (ft) 1722.76 Shear (lb/sq ft) 0.60

Alpha 1.00 Stream Power (lb/ft s) 1164.66 0.00 0.00

Frctn Loss (ft) 0.06 Cum Volume (acre-ft) 2.43 58.80 4.33

C & E Loss (ft) 0.31 Cum SA (acres) 1.82 10.09 2.48

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 100

 

INPUT

Description:

Station Elevation Data num= 25

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1734.26 1001 1734.26 1001.22 1734.34 1011.88 1732.26 1022.27 1730.26

1024.44 1729.86 1027.45 1728.26 1031.2 1726.26 1034.85 1724.26 1038.4 1722.26

1040.93 1720.96 1047.62 1721.3 1102.02 1721.25 1118.34 1721.3 1119.65 1722.26

1123 1724.26 1126.5 1726.26 1130.15 1728.26 1132.68 1729.52 1139.16 1729.71

1142.93 1730.26 1147.57 1730.94 1157.98 1732.26 1158.86 1732.35 1162.48 1732.26

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .03 1022.27 .03 1132.68 .03

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1022.27 1132.68 289.86 295.13 299.75 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1730.08 Element Left OB Channel Right OB

Vel Head (ft) 1.40 Wt. n-Val. 0.030

W.S. Elev (ft) 1728.67 Reach Len. (ft) 289.86 295.13 299.75

Crit W.S. (ft) Flow Area (sq ft) 673.24

E.G. Slope (ft/ft) 0.003222 Area (sq ft) 673.24

Q Total (cfs) 6400.00 Flow (cfs) 6400.00

Top Width (ft) 104.31 Top Width (ft) 104.31

Vel Total (ft/s) 9.51 Avg. Vel. (ft/s) 9.51

Max Chl Dpth (ft) 7.71 Hydr. Depth (ft) 6.45

Conv. Total (cfs) 112750.5 Conv. (cfs) 112750.5

Length Wtd. (ft) 295.13 Wetted Per. (ft) 108.28

Min Ch El (ft) 1720.96 Shear (lb/sq ft) 1.25

Alpha 1.00 Stream Power (lb/ft s) 1162.48 0.00 0.00

Frctn Loss (ft) 1.15 Cum Volume (acre-ft) 2.43 58.45 4.33

C & E Loss (ft) 0.04 Cum SA (acres) 1.82 10.03 2.48

 

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 90

 

INPUT

Description:

Station Elevation Data num= 20

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1728.26 1009.38 1728.01 1031.29 1727.22 1056.45 1726.9 1058.67 1726.26

1065.64 1724.26 1072.62 1722.26 1079.6 1720.26 1086.6 1718.26 1089.42 1717.45

1103.03 1718.26 1124.51 1719.41 1128.2 1720.26 1136.83 1722.26 1145.32 1724.26

1153.73 1726.26 1162.18 1728.26 1168.18 1729.68 1186.62 1730.26 1187.5 1730.28

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .03 1056.45 .03 1168.18 .03

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1056.45 1168.18 495.14 482.19 465.14 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1728.89 Element Left OB Channel Right OB

Vel Head (ft) 1.85 Wt. n-Val. 0.030 0.030

W.S. Elev (ft) 1727.03 Reach Len. (ft) 495.14 482.19 465.14

Crit W.S. (ft) Flow Area (sq ft) 0.68 585.78

E.G. Slope (ft/ft) 0.004781 Area (sq ft) 0.68 585.78

Q Total (cfs) 6400.00 Flow (cfs) 0.38 6399.62

Top Width (ft) 110.92 Top Width (ft) 10.38 100.54

Vel Total (ft/s) 10.91 Avg. Vel. (ft/s) 0.56 10.93

Max Chl Dpth (ft) 9.58 Hydr. Depth (ft) 0.07 5.83

Conv. Total (cfs) 92563.7 Conv. (cfs) 5.5 92558.1

Length Wtd. (ft) 482.19 Wetted Per. (ft) 10.38 102.81

Min Ch El (ft) 1717.45 Shear (lb/sq ft) 0.02 1.70

Alpha 1.00 Stream Power (lb/ft s) 1187.50 0.00 0.00

Frctn Loss (ft) 1.91 Cum Volume (acre-ft) 2.42 54.19 4.33

C & E Loss (ft) 0.15 Cum SA (acres) 1.79 9.33 2.48

 

Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 80

 

INPUT

Description:

Station Elevation Data num= 18

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1728.26 1007.66 1727.66 1115.85 1726.33 1116.84 1726.26 1147.29 1725.45

1152.02 1724.26 1159.92 1722.26 1167.78 1720.26 1175.62 1718.26 1181.94 1716.64

1227.68 1717.16 1232.07 1718.26 1240.31 1720.26 1248.54 1722.26 1256.76 1724.26

1264.99 1726.26 1269.91 1727.47 1287.78 1727.11

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .03 1147.29 .03 1269.91 .03

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1147.29 1269.91 455.76 470.68 481.96 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1726.83 Element Left OB Channel Right OB

Vel Head (ft) 1.35 Wt. n-Val. 0.030 0.030

W.S. Elev (ft) 1725.48 Reach Len. (ft) 455.76 470.68 481.96

Crit W.S. (ft) Flow Area (sq ft) 0.01 686.82

E.G. Slope (ft/ft) 0.003327 Area (sq ft) 0.01 686.82

Q Total (cfs) 6400.00 Flow (cfs) 0.00 6400.00

Top Width (ft) 115.54 Top Width (ft) 1.06 114.48

Vel Total (ft/s) 9.32 Avg. Vel. (ft/s) 0.17 9.32

Max Chl Dpth (ft) 8.84 Hydr. Depth (ft) 0.01 6.00

Conv. Total (cfs) 110961.9 Conv. (cfs) 0.0 110961.8

Length Wtd. (ft) 470.68 Wetted Per. (ft) 1.06 116.59

Min Ch El (ft) 1716.64 Shear (lb/sq ft) 0.00 1.22

Alpha 1.00 Stream Power (lb/ft s) 1287.78 0.00 0.00

Frctn Loss (ft) 2.32 Cum Volume (acre-ft) 2.42 47.14 4.33

C & E Loss (ft) 0.13 Cum SA (acres) 1.73 8.14 2.48

 

Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections.

Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4.

This may indicate the need for additional cross sections.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 70

 

INPUT

Description:

Station Elevation Data num= 17

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1725.56 1084.1 1725.95 1090.63 1724.26 1098.35 1722.26 1106.05 1720.26

1113.75 1718.26 1121.45 1716.26 1129.17 1714.26 1129.24 1714.26 1129.36 1714.26

1169.17 1714.86 1174.59 1716.26 1182.8 1718.26 1191.03 1720.26 1197.56 1721.85

1230.27 1722.26 1233.61 1722.33

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .03 1084.1 .03 1197.56 .03

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1084.1 1197.56 493.27 497.95 498.08 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1724.39 Element Left OB Channel Right OB

Vel Head (ft) 2.61 Wt. n-Val. 0.030

W.S. Elev (ft) 1721.78 Reach Len. (ft) 493.27 497.95 498.08

Crit W.S. (ft) 1721.78 Flow Area (sq ft) 494.02

E.G. Slope (ft/ft) 0.008008 Area (sq ft) 494.02

Q Total (cfs) 6400.00 Flow (cfs) 6400.00

Top Width (ft) 97.06 Top Width (ft) 97.06

Vel Total (ft/s) 12.95 Avg. Vel. (ft/s) 12.95

Max Chl Dpth (ft) 7.52 Hydr. Depth (ft) 5.09

Conv. Total (cfs) 71518.3 Conv. (cfs) 71518.3

Length Wtd. (ft) 497.78 Wetted Per. (ft) 98.87

Min Ch El (ft) 1714.26 Shear (lb/sq ft) 2.50

Alpha 1.00 Stream Power (lb/ft s) 1233.61 0.00 0.00

Frctn Loss (ft) 1.25 Cum Volume (acre-ft) 2.42 40.76 4.33

C & E Loss (ft) 0.62 Cum SA (acres) 1.72 7.00 2.48

 

Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth

for the water surface and continued on with the calculations.

Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections.

Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4.

This may indicate the need for additional cross sections.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated

water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program

defaulted to critical depth.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 60

 

INPUT

Description:

Station Elevation Data num= 31

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1722.26 1013.98 1720.62 1035.26 1720.26 1105.92 1719.84 1119.77 1720.26

1120.01 1720.26 1120.14 1720.27 1128.57 1718.26 1136.9 1716.26 1145.29 1714.26

1153.14 1712.36 1183.08 1712.26 1194.72 1712.2 1194.99 1712.26 1203.55 1714.26

1212.13 1716.26 1220.71 1718.26 1223.41 1718.89 1277.47 1719.61 1286.74 1720.31

1287.48 1720.26 1296.95 1720.26 1310.09 1719.74 1314.87 1720.26 1321.04 1720.95

1336.07 1720.26 1343.02 1719.88 1362.12 1720.26 1381.28 1720.99 1394.59 1720.66

1400.91 1722.26

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .03 1120.14 .03 1223.41 .03

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1120.14 1223.41 499.62 499.27 502.1 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1722.48 Element Left OB Channel Right OB

Vel Head (ft) 0.54 Wt. n-Val. 0.030 0.030 0.030

W.S. Elev (ft) 1721.94 Reach Len. (ft) 499.62 499.27 502.10

Crit W.S. (ft) Flow Area (sq ft) 199.37 769.87 335.48

E.G. Slope (ft/ft) 0.001217 Area (sq ft) 199.37 769.87 335.48

Q Total (cfs) 6400.00 Flow (cfs) 490.08 5020.71 889.21

Top Width (ft) 396.88 Top Width (ft) 117.39 103.27 176.23

Vel Total (ft/s) 4.91 Avg. Vel. (ft/s) 2.46 6.52 2.65

Max Chl Dpth (ft) 9.74 Hydr. Depth (ft) 1.70 7.45 1.90

Conv. Total (cfs) 183480.4 Conv. (cfs) 14049.9 143937.8 25492.7

Length Wtd. (ft) 499.48 Wetted Per. (ft) 117.48 104.97 176.54

Min Ch El (ft) 1712.20 Shear (lb/sq ft) 0.13 0.56 0.14

Alpha 1.45 Stream Power (lb/ft s) 1400.91 0.00 0.00

Frctn Loss (ft) 0.84 Cum Volume (acre-ft) 1.29 33.54 2.41

C & E Loss (ft) 0.04 Cum SA (acres) 1.05 5.85 1.47

 

Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4.

This may indicate the need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 50

 

INPUT

Description:

Station Elevation Data num= 21

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1725.26 1020.92 1724.26 1037.11 1723.68 1066.67 1722.82 1068.75 1722.26

1076.4 1720.26 1084.26 1718.26 1092.32 1716.26 1100.45 1714.26 1108.62 1712.26

1112.98 1711.16 1152.91 1711.26 1158.04 1712.26 1168.25 1714.26 1178.41 1716.26

1181.82 1716.86 1195.46 1718.26 1207.5 1719.4 1214.02 1720.26 1235.55 1722.26

1249.78 1722.26

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .03 1066.67 .03 1235.55 .03

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1066.67 1235.55 334.29 305.6 277.63 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1721.59 Element Left OB Channel Right OB

Vel Head (ft) 0.95 Wt. n-Val. 0.030

W.S. Elev (ft) 1720.64 Reach Len. (ft) 334.29 305.60 277.63

Crit W.S. (ft) Flow Area (sq ft) 817.62

E.G. Slope (ft/ft) 0.002491 Area (sq ft) 817.62

Q Total (cfs) 6400.00 Flow (cfs) 6400.00

Top Width (ft) 143.21 Top Width (ft) 143.21

Vel Total (ft/s) 7.83 Avg. Vel. (ft/s) 7.83

Max Chl Dpth (ft) 9.48 Hydr. Depth (ft) 5.71

Conv. Total (cfs) 128232.2 Conv. (cfs) 128232.2

Length Wtd. (ft) 305.16 Wetted Per. (ft) 145.11

Min Ch El (ft) 1711.16 Shear (lb/sq ft) 0.88

Alpha 1.00 Stream Power (lb/ft s) 1249.78 0.00 0.00

Frctn Loss (ft) 1.04 Cum Volume (acre-ft) 0.15 24.44 0.48

C & E Loss (ft) 0.10 Cum SA (acres) 0.38 4.44 0.45

 

Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections.

Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4.

This may indicate the need for additional cross sections.

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 40

 

INPUT

Description:

Station Elevation Data num= 20

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1720.26 1101.53 1719.38 1146.2 1718.26 1152.03 1718.11 1159.77 1716.26

1168.18 1714.26 1176.59 1712.26 1185.01 1710.26 1186.07 1710.01 1196.73 1709.64

1216.01 1709.46 1218.57 1710.26 1225.27 1712.26 1231.97 1714.26 1238.76 1716.26

1239.39 1716.36 1283.03 1718.26 1284.32 1718.43 1316.26 1719.03 1327.96 1720.26

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .03 1146.2 .03 1238.76 .03

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1146.2 1238.76 500.14 491.57 481.13 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1720.45 Element Left OB Channel Right OB

Vel Head (ft) 1.93 Wt. n-Val. 0.030 0.030 0.030

W.S. Elev (ft) 1718.53 Reach Len. (ft) 500.14 491.57 481.13

Crit W.S. (ft) 1718.08 Flow Area (sq ft) 1.40 548.27 54.91

E.G. Slope (ft/ft) 0.004994 Area (sq ft) 1.40 548.27 54.91

Q Total (cfs) 6400.00 Flow (cfs) 1.28 6196.01 202.71

Top Width (ft) 153.78 Top Width (ft) 10.58 92.56 50.64

Vel Total (ft/s) 10.59 Avg. Vel. (ft/s) 0.91 11.30 3.69

Max Chl Dpth (ft) 9.07 Hydr. Depth (ft) 0.13 5.92 1.08

Conv. Total (cfs) 90560.6 Conv. (cfs) 18.1 87674.1 2868.4

Length Wtd. (ft) 491.42 Wetted Per. (ft) 10.59 94.51 50.70

Min Ch El (ft) 1709.46 Shear (lb/sq ft) 0.04 1.81 0.34

Alpha 1.11 Stream Power (lb/ft s) 1327.96 0.00 0.00

Frctn Loss (ft) 2.69 Cum Volume (acre-ft) 0.14 19.65 0.30

C & E Loss (ft) 0.02 Cum SA (acres) 0.34 3.62 0.29

 

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 30

 

INPUT

Description:

Station Elevation Data num= 16

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1716.56 1012.26 1716.26 1053.23 1714.67 1055.19 1714.26 1064.74 1712.26

1074.25 1710.26 1083.68 1708.26 1084.33 1708.12 1124.71 1708.11 1125.31 1708.26

1133.14 1710.26 1140.87 1712.26 1148.55 1714.26 1154.72 1715.87 1175.89 1716.26

1316.21 1718.06

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .03 1053.23 .03 1154.72 .03

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1053.23 1154.72 494.86 498.03 503.84 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1717.75 Element Left OB Channel Right OB

Vel Head (ft) 2.12 Wt. n-Val. 0.030 0.030

W.S. Elev (ft) 1715.62 Reach Len. (ft) 494.86 498.03 503.84

Crit W.S. (ft) 1715.26 Flow Area (sq ft) 11.70 544.04

E.G. Slope (ft/ft) 0.006016 Area (sq ft) 11.70 544.04

Q Total (cfs) 6400.00 Flow (cfs) 27.39 6372.61

Top Width (ft) 125.09 Top Width (ft) 24.55 100.54

Vel Total (ft/s) 11.52 Avg. Vel. (ft/s) 2.34 11.71

Max Chl Dpth (ft) 7.51 Hydr. Depth (ft) 0.48 5.41

Conv. Total (cfs) 82515.6 Conv. (cfs) 353.2 82162.5

Length Wtd. (ft) 498.02 Wetted Per. (ft) 24.57 102.18

Min Ch El (ft) 1708.11 Shear (lb/sq ft) 0.18 2.00

Alpha 1.03 Stream Power (lb/ft s) 1316.21 0.00 0.00

Frctn Loss (ft) 2.84 Cum Volume (acre-ft) 0.07 13.49 0.00

C & E Loss (ft) 0.09 Cum SA (acres) 0.14 2.53 0.01

 

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 20

 

INPUT

Description:

Station Elevation Data num= 17

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1714.26 1182.02 1714.23 1190.86 1712.26 1199.75 1710.26 1208.56 1708.26

1217.31 1706.26 1221.12 1705.38 1267.53 1705.85 1269.51 1706.26 1279.06 1708.26

1288.6 1710.26 1298.12 1712.26 1307.42 1714.21 1307.8 1714.26 1322.04 1715.71

1343.21 1714.96 1500.75 1715.96

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .03 1182.02 .03 1322.04 .03

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1182.02 1322.04 483.22 488.53 497.54 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1714.81 Element Left OB Channel Right OB

Vel Head (ft) 1.82 Wt. n-Val. 0.030

W.S. Elev (ft) 1713.00 Reach Len. (ft) 483.22 488.53 497.54

Crit W.S. (ft) Flow Area (sq ft) 591.53

E.G. Slope (ft/ft) 0.005415 Area (sq ft) 591.53

Q Total (cfs) 6400.00 Flow (cfs) 6400.00

Top Width (ft) 114.06 Top Width (ft) 114.06

Vel Total (ft/s) 10.82 Avg. Vel. (ft/s) 10.82

Max Chl Dpth (ft) 7.62 Hydr. Depth (ft) 5.19

Conv. Total (cfs) 86970.7 Conv. (cfs) 86970.7

Length Wtd. (ft) 488.53 Wetted Per. (ft) 115.66

Min Ch El (ft) 1705.38 Shear (lb/sq ft) 1.73

Alpha 1.00 Stream Power (lb/ft s) 1500.75 0.00 0.00

Frctn Loss (ft) 2.26 Cum Volume (acre-ft) 6.99 0.00

C & E Loss (ft) 0.10 Cum SA (acres) 1.30 0.01

 

Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the

need for additional cross sections.

 

CROSS SECTION

 

 

RIVER: RIVER-1

REACH: Reach-1 RS: 10

 

INPUT

Description:

Station Elevation Data num= 18

Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev

1000 1712.26 1002.71 1712.33 1003.06 1712.26 1012.39 1710.26 1021.7 1708.26

1031.01 1706.26 1040.32 1704.26 1042.48 1703.8 1049.9 1702.59 1089.4 1702.81

1095.84 1704.26 1104.89 1706.26 1114.24 1708.26 1123.66 1710.26 1126.64 1710.86

1152.79 1712.26 1160.64 1712.67 1288.04 1714.26

 

Manning's n Values num= 3

Sta n Val Sta n Val Sta n Val

1000 .03 1000 .03 1126.64 .03

 

Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan.

1000 1126.64 0 0 0 .1 .3

 

CROSS SECTION OUTPUT Profile #PF 1

E.G. Elev (ft) 1712.45 Element Left OB Channel Right OB

Vel Head (ft) 1.48 Wt. n-Val. 0.030 0.030

W.S. Elev (ft) 1710.97 Reach Len. (ft)

Crit W.S. (ft) 1709.67 Flow Area (sq ft) 655.74 0.11

E.G. Slope (ft/ft) 0.004002 Area (sq ft) 655.74 0.11

Q Total (cfs) 6400.00 Flow (cfs) 6399.95 0.05

Top Width (ft) 119.62 Top Width (ft) 117.56 2.06

Vel Total (ft/s) 9.76 Avg. Vel. (ft/s) 9.76 0.45

Max Chl Dpth (ft) 8.38 Hydr. Depth (ft) 5.58 0.06

Conv. Total (cfs) 101168.4 Conv. (cfs) 101167.5 0.8

Length Wtd. (ft) Wetted Per. (ft) 119.28 2.06

Min Ch El (ft) 1702.59 Shear (lb/sq ft) 1.37 0.01

Alpha 1.00 Stream Power (lb/ft s) 1288.04 0.00 0.00

Frctn Loss (ft) Cum Volume (acre-ft)

C & E Loss (ft) Cum SA (acres)

 

 

SUMMARY OF MANNING'S N VALUES

 

River:RIVER-1

Reach River Sta. n1 n2 n3

Reach-1 390 .025 .015 .025

Reach-1 380 .025 .015 .025

Reach-1 370 .025 .015 .025

Reach-1 360 .025 .015 .025

Reach-1 350 .025 .015 .025

Reach-1 340 .025 .015 .025

Reach-1 338 .025 .015 .025

Reach-1 337 .025 .015 .025

Reach-1 335 .035 .035 .035

Reach-1 334 .035 .035 .035

Reach-1 330 .035 .035 .035

Reach-1 320 .02 .02 .02

Reach-1 310 .02 .015 .02

Reach-1 300 .02 .015 .02

Reach-1 295 Bridge

Reach-1 290 .02 .015 .02

Reach-1 280 .02 .015 .02

Reach-1 270 .02 .015 .02

Reach-1 260 .02 .015 .02

Reach-1 250 .02 .015 .02

Reach-1 240 .02 .02 .02

Reach-1 230 .02 .02 .02

Reach-1 220 .02 .02 .02

Reach-1 210 .02 .02 .02

Reach-1 200 .02 .02 .02

Reach-1 190 .02 .02 .02

Reach-1 180 .02 .02 .02

Reach-1 170 .02 .02 .02

Reach-1 160 .02 .02 .02

Reach-1 150 .02 .02 .02

Reach-1 140 .02 .015 .02

Reach-1 130 .02 .015 .02

Reach-1 125 Bridge

Reach-1 120 .03 .015 .03

Reach-1 110 .03 .015 .03

Reach-1 100 .03 .03 .03

Reach-1 90 .03 .03 .03

Reach-1 80 .03 .03 .03

Reach-1 70 .03 .03 .03

Reach-1 60 .03 .03 .03

Reach-1 50 .03 .03 .03

Reach-1 40 .03 .03 .03

Reach-1 30 .03 .03 .03

Reach-1 20 .03 .03 .03

Reach-1 10 .03 .03 .03

 

 

SUMMARY OF REACH LENGTHS

 

River: RIVER-1

Reach River Sta. Left Channel Right

Reach-1 390 420.9 420.9 420.21

Reach-1 380 170 170.96 173

Reach-1 370 222 232.15 238

Reach-1 360 323 314.29 310

Reach-1 350 439 436.71 435

Reach-1 340 85 85 85

Reach-1 338 95 95 95

Reach-1 337 60 60 60

Reach-1 335 40 40 40

Reach-1 334 210 210 210

Reach-1 330 343.49 343.49 343.49

Reach-1 320 489.89 489.1 487.69

Reach-1 310 102.64 100.28 105.7

Reach-1 300 102.54 102.75 98.55

Reach-1 295 Bridge

Reach-1 290 14.68 14.95 12.7

Reach-1 280 1 1 1

Reach-1 270 33.84 21.92 8.99

Reach-1 260 1 1 1

Reach-1 250 57.45 58.6 58.44

Reach-1 240 496.31 492 488.69

Reach-1 230 490.46 494.76 498.91

Reach-1 220 464.69 476.72 489.34

Reach-1 210 499.74 500.38 500.05

Reach-1 200 494.16 495.37 496.56

Reach-1 190 499.18 497.74 497.1

Reach-1 180 490.6 491.83 492.37

Reach-1 170 486.67 487.26 487.82

Reach-1 160 501.43 501.51 502.7

Reach-1 150 491.39 489.94 488.88

Reach-1 140 64.74 64.14 64.09

Reach-1 130 120.77 119.69 117.86

Reach-1 125 Bridge

Reach-1 120 88.77 90.11 93.13

Reach-1 110 25.99 25.69 26.18

Reach-1 100 289.86 295.13 299.75

Reach-1 90 495.14 482.19 465.14

Reach-1 80 455.76 470.68 481.96

Reach-1 70 493.27 497.95 498.08

Reach-1 60 499.62 499.27 502.1

Reach-1 50 334.29 305.6 277.63

Reach-1 40 500.14 491.57 481.13

Reach-1 30 494.86 498.03 503.84

Reach-1 20 483.22 488.53 497.54

Reach-1 10 0 0 0

 

 

SUMMARY OF CONTRACTION AND EXPANSION COEFFICIENTS

River: RIVER-1

 

Reach River Sta. Contr. Expan.

Reach-1 390 .1 .3

Reach-1 380 .1 .3

Reach-1 370 .1 .3

Reach-1 360 .1 .3

Reach-1 350 .1 .3

Reach-1 340 .1 .3

Reach-1 338 .1 .3

Reach-1 337 .1 .3

Reach-1 335 .1 .3

Reach-1 334 .1 .3

Reach-1 330 .1 .3

Reach-1 320 .1 .3

Reach-1 310 .1 .3

Reach-1 300 .1 .3

Reach-1 295 Bridge

Reach-1 290 .1 .3

Reach-1 280 .1 .3

Reach-1 270 .1 .3

Reach-1 260 .1 .3

Reach-1 250 .1 .3

Reach-1 240 .1 .3

Reach-1 230 .1 .3

Reach-1 220 .1 .3

Reach-1 210 .1 .3

Reach-1 200 .1 .3

Reach-1 190 .1 .3

Reach-1 180 .1 .3

Reach-1 170 .1 .3

Reach-1 160 .1 .3

Reach-1 150 .1 .3

Reach-1 140 .1 .3

Reach-1 130 .1 .3

Reach-1 125 Bridge

Reach-1 120 .1 .3

Reach-1 110 .1 .3

Reach-1 100 .1 .3

Reach-1 90 .1 .3

Reach-1 80 .1 .3

Reach-1 70 .1 .3

Reach-1 60 .1 .3

Reach-1 50 .1 .3

Reach-1 40 .1 .3

Reach-1 30 .1 .3

Reach-1 20 .1 .3

Reach-1 10 .1 .3